Skip to product information
1 of 12

Stellmachermed

Tri-Port Liposuction Cannula – 30 cm | 1 Central + 2 Lateral Holes | 3–6 mm

Tri-Port Liposuction Cannula – 30 cm | 1 Central + 2 Lateral Holes | 3–6 mm

SKU:S098715

🔥 sold in last hours
Regular price $44.99
Regular price Sale price $44.99
Sale Sold out
Shipping calculated at checkout.
Diameter

30 Days Free Return

Shipping Free On order $100

View full details

Product Description


Tri-Port Liposuction Cannula – One Central & Two Lateral Holes

The Tri-Port Liposuction Cannula is a professional surgical suction cannula designed for liposuction, fat aspiration, and body-contouring applications. Its distal working end features one central aspiration hole and two lateral aspiration holes, creating a three-port configuration for professional fat-removal procedures.

Each cannula has a consistent 30 cm (approximately 12") working length and is available in 3 mm, 4 mm, 5 mm, and 6 mm diameters. This size range allows surgeons and healthcare facilities to select the diameter appropriate for their procedure, treatment area, and preferred surgical technique.

Manufactured from medical-grade stainless steel, the cannula is designed for professional surgical environments where durability, precise construction, and dependable instrument handling are required.

Key Features

  • Three-port design with one central hole and two lateral holes
  • Consistent 30 cm working length across all variants
  • Available in 3 mm, 4 mm, 5 mm, and 6 mm diameters
  • Designed for professional liposuction and fat-aspiration procedures
  • Multiple distal openings provide three aspiration points at the working end
  • Long shaft provides working reach for body-contouring applications
  • Medical-grade stainless steel construction
  • Multiple diameter options allow selection according to procedural requirements
  • Suitable for plastic, cosmetic, and reconstructive surgical instrument inventories
  • Designed for use by appropriately trained healthcare professionals

Available Sizes & Specifications

SKU Diameter Working Length Port Configuration
S098715 3 mm 30 cm / approx. 12" 1 Central + 2 Lateral Holes
S098716 4 mm 30 cm / approx. 12" 1 Central + 2 Lateral Holes
S098717 5 mm 30 cm / approx. 12" 1 Central + 2 Lateral Holes
S098719 6 mm 30 cm / approx. 12" 1 Central + 2 Lateral Holes

Product Specifications

  • Product Name: Tri-Port Liposuction Cannula
  • Instrument Type: Liposuction / Fat Aspiration Cannula
  • Port Configuration: One Central Hole + Two Lateral Holes
  • Total Aspiration Ports: 3
  • Working Length: 30 cm / approximately 12"
  • Available Diameters: 3 mm, 4 mm, 5 mm, 6 mm
  • Material: Medical-Grade Stainless Steel
  • Specialty: Plastic & Cosmetic Surgery
  • Application: Liposuction and Fat Aspiration
  • Intended User: Trained Healthcare Professionals

Three-Port Aspiration Design

The working tip combines one central opening with two lateral openings. This arrangement provides three aspiration points around the distal portion of the cannula while maintaining a streamlined surgical instrument profile.

The cannula may be incorporated into professional liposuction and body-contouring instrument setups where this specific three-port configuration is preferred.

Uses & Applications

The 30 cm Tri-Port Liposuction Cannula is intended for professional procedures requiring controlled aspiration of adipose tissue. The appropriate diameter should be selected by the healthcare professional according to the procedure, anatomical area, and surgical technique.

  • Professional liposuction procedures
  • Fat aspiration
  • Body contouring and body sculpting
  • Plastic surgery procedures
  • Cosmetic surgical applications
  • Selected reconstructive procedures
  • Professional aesthetic surgery instrument sets
  • Hospital and surgical-center inventories

Choose the Right Diameter

All variants use the same 30 cm length and one-central-plus-two-lateral-hole configuration. The main difference is the outside diameter of the cannula.

3 mm Diameter – S098715

The 3 mm cannula is the narrowest option within this product family and may be selected when a smaller-diameter working profile is preferred.

4 mm Diameter – S098716

The 4 mm cannula provides an intermediate diameter and is suitable for professional procedures where this size is specified by the surgeon's technique.

5 mm Diameter – S098717

The 5 mm cannula provides a wider working profile while retaining the same 30 cm shaft and three-port tip configuration.

6 mm Diameter – S098719

The 6 mm cannula is the largest diameter available within this listing and may be selected where a larger cannula profile is required.

Select the required Diameter from the product options before adding the instrument to your cart.

30 cm Working Length

Every size in this listing has a 30 cm working length. Keeping the shaft length consistent across all four variants allows the user to select the required diameter while retaining the same overall working reach and port configuration.

Medical-Grade Stainless Steel Construction

The cannula is manufactured from medical-grade stainless steel for professional surgical use. Instrument cleaning, inspection, sterilization, maintenance, and storage should be performed according to the applicable product instructions and healthcare facility protocols.

Why Choose This Tri-Port Liposuction Cannula?

  • Three aspiration openings in a central-and-lateral configuration
  • Four practical diameter options
  • Consistent 30 cm working length
  • Professional stainless steel construction
  • Simple diameter-based selection
  • Suitable for professional plastic and aesthetic surgical instrument sets

Explore More Liposuction Instruments

Discover professional surgical instruments and medical equipment from Stellmacher Instruments.

Browse additional sizes, tip configurations, and aspiration designs in our Liposuction Cannulas Collection.

Complete your liposuction instrument setup with the Gold-Plated Cannula Handle – 13 cm Threaded Grip.

Professional Use: This product is intended for use by appropriately trained healthcare professionals. Cannula selection, compatible equipment, surgical technique, cleaning, sterilization, inspection, and maintenance should follow applicable product instructions and healthcare facility protocols.