Tischler-Morgan Biopsy Forceps with Lock – Premium | Mini & Standard
The Tischler-Morgan Biopsy Forceps with Lock are precision surgical biopsy instruments designed for controlled tissue sampling during gynecological, cervical, colposcopy, and related diagnostic procedures. The precision working jaws are designed to obtain a defined tissue specimen while providing the surgeon with controlled handling and access to the target area.
This premium Tischler-Morgan biopsy forceps range is available in both Mini and Standard configurations. The Mini version features a smaller 4.2 x 2.3 x 1mm working jaw for procedures requiring a more compact tissue sample, while the Standard version features a larger 5 x 3 x 1mm jaw for routine biopsy applications.
Both models feature a locking mechanism to help maintain the jaw position when required and provide controlled instrument handling during tissue sampling. The elongated shaft supports access during cervical and gynecological procedures while keeping the handle comfortably positioned outside the operative field.
Available Variants
| SKU | Model | Jaw / Bite Size | Shaft | Lock |
|---|---|---|---|---|
| SM-41510-8M | Mini Tischler-Morgan | 4.2 x 2.3 x 1mm | 8" | Yes |
| SM-41510-8 | Tischler-Morgan Standard | 5 x 3 x 1mm | 8" | Yes |
Key Features
- Tischler-Morgan Pattern: Precision biopsy forceps design for professional gynecological and cervical tissue sampling.
- Mini & Standard Options: Available with 4.2 x 2.3 x 1mm or 5 x 3 x 1mm working jaws to accommodate different tissue-sampling requirements.
- 8" Shaft: Long shaft provides practical reach for cervical and gynecological biopsy procedures.
- Precision Biopsy Jaws: Designed for controlled engagement and removal of tissue specimens.
- Locking Mechanism: Helps secure the working jaws and provides controlled handling during specimen collection.
- Mini Jaw Option: Smaller working end is suitable when a more compact tissue specimen or precise access is required.
- Standard Jaw Option: Larger 5 x 3 x 1mm working end provides a broader biopsy bite for routine tissue sampling.
- Premium Construction: Designed for durability, precision, and repeated professional surgical use.
- Reusable Instrument: Suitable for repeated clinical use following proper cleaning, inspection, and sterilization protocols.
Product Specifications
| Product Name | Tischler-Morgan Biopsy Forceps |
| Instrument Type | Cervical / Gynecological Biopsy Forceps |
| Pattern | Tischler-Morgan |
| Available Models | Mini & Standard |
| Mini Jaw Size | 4.2 x 2.3 x 1mm |
| Standard Jaw Size | 5 x 3 x 1mm |
| Shaft Length | 8" |
| Lock | Yes |
| Quality | Premium |
| Design | Long-Shaft Biopsy Forceps |
| Primary Function | Controlled Tissue Sampling & Biopsy Specimen Collection |
| Application | Gynecology, Cervical Biopsy & Colposcopy Procedures |
| Use Type | Reusable Surgical Instrument |
Mini Tischler-Morgan – 4.2 x 2.3 x 1mm
The Mini Tischler-Morgan Biopsy Forceps feature a compact 4.2 x 2.3 x 1mm working jaw. The smaller biopsy profile is designed for controlled tissue sampling where precise access or a smaller specimen is preferred.
The Mini configuration can be particularly useful when working around confined or delicate anatomical areas where a larger biopsy jaw may provide more tissue engagement than required.
Standard Tischler-Morgan – 5 x 3 x 1mm
The Standard Tischler-Morgan Biopsy Forceps feature a 5 x 3 x 1mm working jaw, providing a larger biopsy bite while maintaining precise control during tissue sampling. This configuration is suitable for routine cervical and gynecological biopsy procedures requiring a defined tissue specimen.
Applications & Uses
- Cervical tissue biopsy
- Colposcopy procedures
- Gynecological tissue sampling
- Collection of tissue specimens for histopathological examination
- Controlled sampling of abnormal or suspicious cervical tissue
- Diagnostic gynecological procedures
- Procedures requiring precise biopsy specimen collection
Precision Working Jaws
The working end of the Tischler-Morgan Biopsy Forceps is designed to provide controlled tissue engagement during biopsy procedures. Selecting either the Mini or Standard jaw allows clinicians to match the working size to procedural and anatomical requirements.
Locking Mechanism
Both variants are supplied with a lock. The locking mechanism supports controlled jaw positioning and helps maintain secure handling of the instrument during biopsy and specimen retrieval.
8-Inch Shaft for Surgical Access
The 8-inch shaft provides extended access for gynecological and cervical procedures while allowing the surgeon to operate the forceps from a practical working distance.
Premium Reusable Surgical Instrument
The Tischler-Morgan Biopsy Forceps are designed for repeated professional surgical use. Appropriate cleaning, inspection, sterilization, and instrument-reprocessing procedures should be followed according to the applicable instructions for use and institutional protocols.
Why Choose Tischler-Morgan Biopsy Forceps?
- Recognized Tischler-Morgan biopsy forceps pattern
- Mini and Standard jaw options
- Precision tissue-sampling design
- Long 8-inch shaft for practical surgical access
- Built-in locking configuration
- Controlled handling during cervical biopsy procedures
- Suitable for gynecology and colposcopy
- Premium reusable surgical instrument
Explore More Surgical Instruments
Explore premium surgical instruments from Stellmacher Instruments, browse our Surgical Instruments Collection, or view the related Kevorkian-Younge Endocervical Biopsy Curette – OB/GYN.
Package Includes
1 × Tischler-Morgan Biopsy Forceps with Lock – selected Mini or Standard variant
Professional Use: Intended for use by qualified healthcare and surgical professionals.