Stellmachermed
Non-Stick Reusable Ball Electrode 4mm x 15cm – Electrosurgical Coagulation Tip
Non-Stick Reusable Ball Electrode 4mm x 15cm – Electrosurgical Coagulation Tip
SKU:SM02US-2046
Couldn't load pickup availability
30 Days Free Return
Shipping Free On order $100
Product Description
Non-Stick Reusable Ball Electrode 4 mm, 15 cm – Electrosurgical Coagulation Tip
The Non-Stick Reusable Ball Electrode by Stellmacher Instruments Inc. is a precision electrosurgical accessory designed for controlled tissue coagulation during compatible monopolar electrosurgical procedures. Featuring a 4 mm rounded ball tip, a 15 cm extended shaft, non-stick surface technology, and durable stainless steel construction, this reusable electrode supports dependable surgical handling and effective energy application.
The rounded ball electrode is designed to distribute electrosurgical energy over a defined contact area for coagulation and hemostasis. Its non-stick surface helps reduce tissue adhesion and the accumulation of carbonized tissue residue during use, supporting more consistent contact and easier tip cleaning.
The insulated shaft and extended working length make this instrument suitable for surgical applications requiring controlled electrode positioning and additional reach.
Key Features & Benefits
- 4 mm Rounded Ball Tip: Designed for controlled contact coagulation and hemostasis during appropriate electrosurgical procedures.
- Non-Stick Coated Surface: Helps minimize tissue adhesion and reduce the buildup of carbonized residue on the working tip.
- 15 cm Extended Length: Provides additional working reach and positioning flexibility during surgical procedures.
- Durable Stainless Steel Construction: Designed with a corrosion-resistant metal structure suitable for repeated professional use.
- Insulated Shaft Design: Features a covered shaft section to provide electrical insulation outside the intended active working area when used within the instrument's rated specifications.
- Reusable & Autoclavable: Designed for repeated use with appropriate cleaning, inspection, and manufacturer-validated steam sterilization procedures.
- Electrosurgical Pencil Integration: Intended for use with compatible electrosurgical handpieces and generators, subject to verified connector dimensions and electrical ratings.
Technical Specifications
| Specification | Details |
|---|---|
| Product Name | Non-Stick Reusable Ball Electrode |
| Instrument Category | Electrosurgical Electrode |
| Electrode Type | Ball / Coagulation |
| Tip Configuration | Rounded Ball |
| Ball Diameter | 4 mm |
| Overall Length | 15 cm (150 mm) |
| Approximate Length | 5.9 Inches |
| Material | Stainless Steel |
| Tip Surface | Non-Stick Coating |
| Shaft Design | Insulated |
| Application | Electrosurgical Coagulation |
| Electrosurgical Mode | Monopolar, subject to device compatibility |
| Construction | Reusable |
| Reprocessing | Autoclavable, according to validated instructions |
| Brand | Stellmacher Instruments Inc. |
Surgical Applications & Intended Usage
1. General Surgery
The reusable ball electrode can be used for appropriate tissue coagulation and hemostasis during general surgical procedures with a compatible electrosurgical system. The rounded working tip supports controlled application to the intended treatment area.
2. Dermatological Procedures
Ball electrodes are used in selected dermatological electrosurgical procedures requiring localized coagulation. The 4 mm rounded tip provides a defined contact surface for appropriate tissue treatment.
3. ENT Surgical Procedures
During suitable ear, nose, and throat procedures, an electrosurgical ball electrode may assist with localized coagulation and bleeding control when the procedure and equipment permit its use.
4. Plastic & Reconstructive Surgery
The rounded electrode configuration can support controlled coagulation during appropriate soft tissue procedures, with the non-stick surface helping reduce adhesion of coagulated material to the tip.
5. Gynecological & Urological Surgery
The 15 cm electrode may be selected for appropriate electrosurgical coagulation applications requiring additional working reach. Selection depends on the procedure, compatible handpiece, and manufacturer-approved intended use.
How to Use the Reusable Ball Electrode
- Inspect the electrode before use, checking the ball tip, insulation, shaft, and connection end for damage.
- Confirm that the electrode is properly cleaned and sterilized according to its validated reprocessing instructions.
- Verify compatibility with the electrosurgical pencil, generator, and intended operating settings.
- Securely connect the electrode to the compatible handpiece following the equipment manufacturer's instructions.
- Perform coagulation only according to the established clinical procedure and the electrosurgical system's instructions for use.
- After use, allow the electrode to cool and follow the approved cleaning, inspection, and reprocessing procedure.
Important: Use only by appropriately trained healthcare professionals. Do not use an electrode with damaged insulation, visible tip deterioration, an insecure connector, or unknown electrical compatibility.
Cleaning, Sterilization & Maintenance
After each procedure, inspect the electrode for tissue residue and visible damage. Clean the rounded ball tip, insulated shaft, and connection areas according to the manufacturer's validated cleaning instructions.
Use cleaning materials compatible with the non-stick surface. Avoid abrasive scrubbing or metal tools that may damage the coating.
Inspect the shaft insulation for cracks, cuts, discoloration, or separation, and verify that the ball tip remains securely attached.
Sterilize using the validated reprocessing cycle specified for the exact product. Do not exceed the manufacturer's stated reuse limits, sterilization temperature, or electrical operating ratings.
Why Choose Stellmacher Instruments Inc.?
Stellmacher Instruments Inc. supplies precision surgical instruments, electrosurgical electrodes, and professional medical accessories for healthcare applications. Our range includes reusable ball electrodes, needle electrodes, blade electrodes, and specialized electrosurgical instruments.
Explore additional products from our official store:
- Stellmacher Instruments – Official Website — Browse our complete selection of surgical instruments and medical accessories.
- Electrosurgical Electrodes Collection — Explore reusable ball, blade, needle, and other electrosurgical electrodes.
- Reusable Ball Electrode – 6 mm, 7 cm — Discover another ball electrode configuration for different clinical requirements.
Stellmacher Instruments Inc. — Precision Electrosurgical Instruments for Professional Use.