{"product_id":"lasik-marker-with-optical-center-sight-titanium","title":"LASIK Marker with Optical Center Sight – Titanium","description":"\u003ch2\u003e\u003cspan\u003eLASIK Marker with Optical Center Sight – Titanium\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe LASIK Marker from \u003c\/span\u003e\u003ca href=\"https:\/\/www.stellmachermed.com\/\"\u003e\u003cspan\u003eStellmacher Instruments Inc.\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e is a specialized ophthalmic surgical instrument designed for corneal reference marking during LASIK (Laser-Assisted In Situ Keratomileusis) and refractive surgical procedures. Featuring an 8.50 mm optical zone and an integrated optical center sight, this instrument assists surgeons in establishing corneal orientation and visual reference markings for corneal flap alignment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eManufactured from lightweight titanium, the instrument features a circular marking head, angled shaft, and textured round handle for controlled manipulation. Its 130 mm overall length provides a practical balance between surgical reach and maneuverability, making it a valuable addition to professional refractive surgery instrument sets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIntegrated Optical Center Sight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides a central visual reference for corneal marking and orientation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e8.50 mm Optical Zone:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Features a defined marking diameter for specialized LASIK applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTitanium Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lightweight material with inherent corrosion resistance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCircular Marking Head:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports defined corneal reference marking and flap orientation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTextured Round Handle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Facilitates stable fingertip grip and controlled instrument positioning.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAngled Shaft Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports access and visibility around the working end.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e130 mm Overall Length:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for controlled handling during delicate ophthalmic procedures.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 55.5878%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 38.653%;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 61.0542%;\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eLASIK Marker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eSKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eSM-0641T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eTitanium\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eOptical Zone Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003e8.50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eOverall Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003e130 mm (13 cm \/ 5.12 inches)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eMarking Head\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eCircular with Optical Center Sight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eShaft Design\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eAngled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eHandle Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eRound with Textured Grip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eColor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eBlue\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eInstrument Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eOphthalmic Corneal Markers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eSurgical Specialty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eRefractive Surgery \/ Ophthalmology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.653%;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0542%;\"\u003e\u003cspan\u003eStellmacher Instruments Inc.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eClinical Applications \u0026amp; Uses\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe titanium LASIK Marker is designed for specialized ophthalmic applications requiring corneal reference markings and optical zone identification during refractive surgery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTypical applications of this instrument pattern include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCorneal reference marking during LASIK surgery.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptical zone identification.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCorneal flap orientation and alignment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCentral reference marking on the corneal surface.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpecialized refractive ophthalmic procedures.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe integrated optical center sight provides a visual reference to assist surgeons with instrument alignment during corneal marking procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eExplore our comprehensive collection of \u003c\/span\u003e\u003ca href=\"https:\/\/stellmachermed.com\/collections\/ophthalmic-instruments\"\u003e\u003cspan\u003eophthalmic surgical instruments\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for additional corneal markers, measuring instruments, and specialized refractive surgery instruments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRelated Ophthalmic Instruments\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor additional corneal centration and optical zone marking applications, explore our \u003c\/span\u003e\u003ca href=\"https:\/\/stellmachermed.com\/products\/hoffer-corneal-marker-with-cross-hairs-7-0-mm-overall-length-12-5-cm\"\u003e\u003cspan\u003eHoffer Corneal Marker with Crosshairs – 7.0 mm\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, a complementary ophthalmic instrument featuring a circular marking head with central reference crosshairs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eInstrument Care\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFollow the manufacturer's instructions for use, cleaning, handling, and applicable sterilization requirements. Intended for use by qualified healthcare professionals.\u003c\/span\u003e\u003c\/p\u003e","brand":"Stellmachermed","offers":[{"title":"Default Title","offer_id":68138495344745,"sku":"SM-0641T","price":122.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0575\/6583\/9465\/files\/SM-0641T-29.jpg?v=1795256871","url":"https:\/\/stellmachermed.com\/products\/lasik-marker-with-optical-center-sight-titanium","provider":"Stellmacher Instruments inc.","version":"1.0","type":"link"}